TIP
This is a device configuration operator. Aggregate configuration operators are recommended in lieu of device configuration operators for interfacing with Open Ephys Onix hardware.
Configures an array of Triad Semiconductor TS4231 lighthouse receivers for 3D position tracking using a pair of SteamVR V1 base stations.
This configuration operator can be linked to a data IO operator, such as TS4231V1PositionData, using a shared DeviceName
to stream 3D
position data from light-house receivers when SteamVR V1 base stations have been installed above the
arena.
Inputs & Outputs
Configures a TS4231 receiver array.
This will schedule configuration actions to be applied by a StartAcquisition instance prior to data acquisition.
|
|
|
Properties
Property | Type | Description |
---|---|---|
Enable
|
bool |
Gets or sets the device enable state. If set to true, a TS4231V1Data instance that is linked to this configuration will produce data. If set to false, it will not produce data. |
DeviceName
|
string |
Gets or sets a unique device name. The device name provides a unique, human-readable identifier that is used to link software elements for configuration, control, and data streaming to hardware. For instance, it can be used to link configuration operators to data IO operators within a workflow. This value is usually not set manually, but is assigned in a MultiDeviceFactory to correspond to a fixed address with a piece of hardware such as a headstage. This address is used for software communication. |
DeviceAddress
|
uint |
Gets or sets the device address. This is a fully-qualified numerical hardware address of a device within the device table produced by an Open Neuro Interface (ONI) compliant acquisition system. This value is usually not set manually, but is assigned in a MultiDeviceFactory to correspond to a fixed address with a piece of hardware such as a headstage. This address is used for hardware communication. |
DeviceType
|
Type |
Gets or sets the device identity. This type provides a device identity to each device within the device table produced by an Open Neuro Interface (ONI) compliant acquisition system. |